Oregon Water Resources Department
Well Log Information System
Well Log:
UMAT 4071
Main
Help
Return
Contact Us
Well Information
(Click to Collapse...)
Identification
Type of Report:
Water Well
Type of Work:
DEEPENING
Well Report:
UMAT
4071
View Log
Groundwater Site
Well Label:
Start Card:
Original Report:
UMAT
4073
View Original Log
Owner Well Nbr:
0
Company Job Nbr:
Primary Use:
IRRIGATION
Complete Date:
12/05/1961
Land Owner
Name:
ARCHIE HARRIS
Company:
Address:
TOUCHET, WA 99360
Location
(Click to Collapse...)
Latitude/Longitude
Latitude:
45.98907800
Longitude:
-118.64747400
Horiz. Error:
25.00
ft.
Location
County:
UMAT
TRSQQ:
WM6.00N33.00E23NENE
Tax Map:
Tax Lot:
Lot:
Block:
Subdivision:
Street of Well:
WM District:
23
Surface Elev:
Well Report Mapping Tool
Tax Lots
Note: Tax lot overlay available only for a few counties.
Well Construction
(Click to Collapse...)
Construction
Start Date:
09/18/1961
Completed Date:
12/05/1961
Drill Method:
Depth of Completed Well:
781.00
Est. Depth Drilled:
Special Standards:
Seal Placed Method:
Abandonment Start Date:
Abandonment Completed Date:
Backfill
Backfill Placement:
Backfill Material:
Explosives Used:
Explosive Type:
Explosive Amount:
Filter Pack
Filter Pack:
Filter Pack Material:
Filter Pack Size:
Bore Hole
Row
Diameter (in)
From (ft)
To (ft)
1
12.00
0.00
150.00
2
10.00
150.00
340.00
3
6.50
340.00
781.00
Seal
No data matches search criteria.
Abandonment Log
No data matches search criteria.
Casing/Liner
Row
Casing/Liner
Diameter (in)
Above Land Surface
From Depth
To (ft)
Gauge
Material
Weld
Glue
Thread
Shoe
Inside
Shoe
Outside
Shoe
Other
Shoe
Location
1
Casing
15.00
1.00
150.00
0.250 - Gauge
2
Casing
10.00
0.00
340.00
0.203 - Gauge
Temporary Casing
No data matches search criteria.
Perforations
Row
Method
Material
Casing/Liner
Diameter (in)
From (ft)
To (ft)
Perforation
Size
Screen/Slot
Size Width
Slot Length
Nbr of Slots
1
MILLS
10.00
100.00
340.00
0.250
1.000
550
Screens
No data matches search criteria.
Well Test
(Click to Expand...)
Well Test
Temperature:
Lab Analysis:
Lab Analysis Done By:
Total Dissolved Solids:
Water Quality Concerns:
Well Test
Test Type
Yield (gpm)
Drawdown
Drill Stem/
Pump Depth
Duration (hr)
Calculated Specific Capacity (gpm/ft)
Pump
330.0
108.0
4.0
3.06
Analysis
No data matches search criteria.
Static Water Level
(Click to Expand...)
Static Water Level
Depth First Water:
624.00
Pre-Static Water Level:
Pre-Static Water Level Date:
Post-Static Water Level:
147.00
Post-Static Water Level Date:
12/05/1961
Static Water Level
No data matches search criteria.
Lithology
(Click to Expand...)
Material
Row
From
To
Material
Static Water Level
1
537.00
564.00
GRAY
2
564.00
570.00
BLACK
3
570.00
613.00
GREENISH SHALE
4
613.00
616.00
GRAY
5
616.00
624.00
GRAY SHALE (SOME WATER)
6
624.00
640.00
GRAY
7
640.00
653.00
BROWNISH BLACK (WATER)
8
653.00
745.00
BLACK
9
745.00
781.00
BROWNISH BLACK
Well Constructor
(Click to Expand...)
Bonded Driller Name:
H ANDERSON
Bonded Driller Company:
Bonded Driller Number:
205
Bonded Date Signed:
12/08/1961
Unbonded Name:
Unbonded Company:
Unbonded Number:
Unbonded Date Signed:
Other Name:
Other Affiliation:
Other License Nbr:
Geologist Engineer:
Comments
(Click to Expand...)
No data matches search criteria.
Documents
(Click to Expand...)
Title
Document Type
Source
Download Image
Received Date
UMAT 4071
WELL REPORT
DRILLER
Image
12/18/1961