Oregon Water Resources Department
Well Log Information System
Well Log:
HARN 52232
Main
Help
Return
Contact Us
Well Information
(Click to Collapse...)
Identification
Type of Report:
Water Well
Type of Work:
NEW
Well Report:
HARN
52232
View Log
Groundwater Site
Well Label:
94031
Start Card:
1025730
Original Report:
Owner Well Nbr:
Company Job Nbr:
Primary Use:
IRRIGATION
Complete Date:
06/08/2015
Land Owner
Name:
KEITH RINGER
Company:
Address:
1436 PETERSON SWAMP RD.
COLVILLE, WA 99114
Location
(Click to Collapse...)
Latitude/Longitude
Latitude:
43.44610524
Longitude:
-118.65899537
Horiz. Error:
100.00
ft.
Location
County:
HARN
TRSQQ:
WM24.00S33.00E33SWNE
Tax Map:
Tax Lot:
8501
Lot:
Block:
Subdivision:
Street of Well:
APPROX. 1/2 A MILE WEST OF QUINCY RD.
WM District:
10
Surface Elev:
Well Report Mapping Tool
Tax Lots
Note: Tax lot overlay available only for a few counties.
Well Construction
(Click to Collapse...)
Construction
Start Date:
03/10/2015
Completed Date:
06/08/2015
Drill Method:
Cable
Depth of Completed Well:
450.00
Est. Depth Drilled:
450.00
Special Standards:
Seal Placed Method:
Abandonment Start Date:
Abandonment Completed Date:
Backfill
Backfill Placement:
ft to ft
Backfill Material:
Explosives Used:
Explosive Type:
Explosive Amount:
Filter Pack
Filter Pack:
Filter Pack Material:
Filter Pack Size:
Bore Hole
Row
Diameter (in)
From (ft)
To (ft)
1
20.00
0.00
40.00
2
12.00
40.00
350.00
3
8.00
350.00
450.00
Seal
Row
Material
From (ft)
To (ft)
Amount
Amount Calc.
1
Bentonite Chips
0.00
40.00
81.00
77.05
Abandonment Log
No data matches search criteria.
Casing/Liner
Row
Casing/Liner
Diameter (in)
Above Land Surface
From Depth
To (ft)
Gauge
Material
Weld
Glue
Thread
Shoe
Inside
Shoe
Outside
Shoe
Other
Shoe
Location
1
Casing
12.00
●
2.00
198.00
.250
Steel
●
●
198.00
Temporary Casing
No data matches search criteria.
Perforations
No data matches search criteria.
Screens
No data matches search criteria.
Well Test
(Click to Expand...)
Well Test
Temperature:
62 F
Lab Analysis:
Lab Analysis Done By:
Total Dissolved Solids:
318.00
Water Quality Concerns:
Well Test
Test Type
Yield (gpm)
Drawdown
Drill Stem/
Pump Depth
Duration (hr)
Calculated Specific Capacity (gpm/ft)
Pump
600.0
90.0
180.00
8.0
6.67
Analysis
No data matches search criteria.
Static Water Level
(Click to Expand...)
Static Water Level
Depth First Water:
47.00
Pre-Static Water Level:
Pre-Static Water Level Date:
Post-Static Water Level:
30.00
Post-Static Water Level Date:
06/08/2015
Static Water Level
Row
Date
From(ft)
To(ft)
SWL
Est. Flow Rate
PSI
1
3/26/2015
47.00
279.00
30.00
10.0
2
5/22/2015
341.00
350.00
30.00
500.0
Lithology
(Click to Expand...)
Material
Row
From
To
Material
Static Water Level
1
0.00
2.00
TOPSOIL
2
2.00
47.00
BROWN CLAY
3
47.00
131.00
GRAY CLAY- FINE SAND
4
131.00
218.00
GREEN CLAY- CINDERS
5
218.00
279.00
WHITE CLAY- PUMICE
6
279.00
312.00
GRAY CLAY
7
312.00
341.00
BLACK CLAY
8
341.00
450.00
BLACK CLAY- FINE SAND
Well Constructor
(Click to Expand...)
Bonded Driller Name:
GEORGE VALENTINE
Bonded Driller Company:
VALENTINE DRILLING
Bonded Driller Number:
1675
Bonded Date Signed:
07/09/2015
Unbonded Name:
Unbonded Company:
Unbonded Number:
Unbonded Date Signed:
Other Name:
Other Affiliation:
Other License Nbr:
Geologist Engineer:
No data matches search criteria.
Documents
(Click to Expand...)
Title
Document Type
Source
Download Image
Received Date
HARN 52232
WELL REPORT
DRILLER
Image
7/9/2015