Oregon Water Resources Department
Well Log Information System
Well Log:
DESC 791
Main
Help
Return
Contact Us
Well Information
(Click to Collapse...)
Identification
Type of Report:
Water Well
Type of Work:
NEW
Well Report:
DESC
791
View Log
Groundwater Site
Well Label:
Start Card:
25017
Original Report:
Owner Well Nbr:
Company Job Nbr:
Primary Use:
IRRIGATION
Complete Date:
02/20/1991
Land Owner
Name:
R L COATS
Company:
Address:
BOX 1008
BEND, OR 97701
Location
(Click to Collapse...)
Latitude/Longitude
Latitude:
43.72215730
Longitude:
-120.32592779
Horiz. Error:
100.00
ft.
Location
County:
DESC
TRSQQ:
WM21.00S20.00E28SWNE
Tax Map:
Tax Lot:
2400
Lot:
Block:
Subdivision:
Street of Well:
2140 NW HWY 20
WM District:
24
Surface Elev:
Well Report Mapping Tool
Tax Lots
Note: Tax lot overlay available only for a few counties.
Well Construction
(Click to Collapse...)
Construction
Start Date:
01/21/1991
Completed Date:
02/20/1991
Drill Method:
Cable
Depth of Completed Well:
412.00
Est. Depth Drilled:
412.00
Special Standards:
Seal Placed Method:
OTHER - POURED & VIBRATED
Abandonment Start Date:
Abandonment Completed Date:
Backfill
Backfill Placement:
ft to ft
Backfill Material:
Explosives Used:
Explosive Type:
Explosive Amount:
Filter Pack
Filter Pack:
Filter Pack Material:
Filter Pack Size:
Bore Hole
Row
Diameter (in)
From (ft)
To (ft)
1
28.00
0.00
20.00
2
17.50
20.00
355.00
Seal
No data matches search criteria.
Abandonment Log
No data matches search criteria.
Casing/Liner
Row
Casing/Liner
Diameter (in)
Above Land Surface
From Depth
To (ft)
Gauge
Material
Weld
Glue
Thread
Shoe
Inside
Shoe
Outside
Shoe
Other
Shoe
Location
1
Casing
20.00
●
1.00
22.00
.250
Steel
●
2
Liner
16.00
●
1.00
355.00
.250
Steel
●
Temporary Casing
No data matches search criteria.
Perforations
Row
Method
Material
Casing/Liner
Diameter (in)
From (ft)
To (ft)
Perforation
Size
Screen/Slot
Size Width
Slot Length
Nbr of Slots
1
FACTORY CUT
Liner
16.00
166.00
355.00
0.125
3.000
4158
Screens
No data matches search criteria.
Well Test
(Click to Expand...)
Well Test
Temperature:
60 F
Lab Analysis:
Lab Analysis Done By:
Total Dissolved Solids:
Water Quality Concerns:
Well Test
Test Type
Yield (gpm)
Drawdown
Drill Stem/
Pump Depth
Duration (hr)
Calculated Specific Capacity (gpm/ft)
Pump
2300.0
50.0
6.5
46.00
Analysis
No data matches search criteria.
Static Water Level
(Click to Expand...)
Static Water Level
Depth First Water:
207.00
Pre-Static Water Level:
Pre-Static Water Level Date:
Post-Static Water Level:
140.00
Post-Static Water Level Date:
02/20/1991
Static Water Level
Row
Date
From(ft)
To(ft)
SWL
Est. Flow Rate
PSI
1
207.00
412.00
140.00
3000.0
Lithology
(Click to Expand...)
Material
Row
From
To
Material
Static Water Level
1
0.00
1.00
TOPSOIL SANDY LOAM
2
1.00
3.00
CLAY BRN
3
3.00
26.00
CLAY SAND BRN
4
26.00
37.00
CONGLOMERATE
5
37.00
57.00
SANDSTONE GREY (HARD)
6
57.00
70.00
CONGLOMERATE
7
70.00
94.00
CLAY/GRAVEL
8
94.00
107.00
CLAY/SILT BRN
9
107.00
137.00
CLAY/SILT GREY
10
137.00
207.00
ROCK BRN
11
207.00
230.00
CLAY YELLOW, GRAVEL MED
140.00
12
230.00
237.00
GRAVEL SAND FINE BLK
140.00
13
237.00
255.00
PUMICE BRN
140.00
14
255.00
260.00
SAND COARSE, FINE BRN, PUMICE
140.00
15
260.00
340.00
PUMICE GREY
140.00
16
340.00
350.00
SANDSTONE SOFT
140.00
17
350.00
370.00
SAND MED, PUMICE
140.00
18
370.00
404.00
PUMICE GREY
140.00
19
404.00
412.00
SANDSTONE BRN
140.00
Well Constructor
(Click to Expand...)
Bonded Driller Name:
JOHN MCALLISTER
Bonded Driller Company:
WESTERN BIG R INC.
Bonded Driller Number:
426
Bonded Date Signed:
02/28/1991
Unbonded Name:
Unbonded Company:
Unbonded Number:
Unbonded Date Signed:
Other Name:
Other Affiliation:
Other License Nbr:
Geologist Engineer:
No data matches search criteria.
Documents
(Click to Expand...)
Title
Document Type
Source
Download Image
DESC 791
WELL REPORT
DRILLER
Image