Oregon Water Resources Department
Well Log Information System
Well Log:
DESC 6092
Main
Help
Return
Contact Us
Well Information
(Click to Collapse...)
Identification
Type of Report:
Water Well
Type of Work:
DEEPENING
Well Report:
DESC
6092
View Log
Groundwater Site
Well Label:
Start Card:
Original Report:
DESC
6090
View Original Log
Owner Well Nbr:
Company Job Nbr:
398-86-10
Primary Use:
COMMUNITY
Complete Date:
06/20/1986
Land Owner
Name:
Company:
OREGON WATER WONDERLAND WATER IMPROVEMENT DISTRICT
Address:
55579 S CENTURY DR
BEND, OR 97707
Location
(Click to Collapse...)
Latitude/Longitude
Latitude:
43.81797316
Longitude:
-121.48202082
Horiz. Error:
100.00
ft.
Location
County:
DESC
TRSQQ:
WM20.00S10.00E25NWNW
Tax Map:
Tax Lot:
Lot:
Block:
Subdivision:
Street of Well:
OREGON WATER WONDERLAND
WM District:
11
Surface Elev:
Well Report Mapping Tool
Tax Lots
Note: Tax lot overlay available only for a few counties.
Well Construction
(Click to Collapse...)
Construction
Start Date:
05/27/1986
Completed Date:
06/20/1986
Drill Method:
Cable
Depth of Completed Well:
642.00
Est. Depth Drilled:
647.00
Special Standards:
Seal Placed Method:
OTHER - UNDISTURBED
Abandonment Start Date:
Abandonment Completed Date:
Backfill
Backfill Placement:
ft to ft
Backfill Material:
Explosives Used:
Explosive Type:
Explosive Amount:
Filter Pack
Filter Pack:
Filter Pack Material:
Filter Pack Size:
Bore Hole
Row
Diameter (in)
From (ft)
To (ft)
1
8.00
385.00
647.00
Seal
No data matches search criteria.
Abandonment Log
No data matches search criteria.
Casing/Liner
Row
Casing/Liner
Diameter (in)
Above Land Surface
From Depth
To (ft)
Gauge
Material
Weld
Glue
Thread
Shoe
Inside
Shoe
Outside
Shoe
Other
Shoe
Location
1
Casing
8.00
385.00
575.00
0.250 - Gauge
Steel
●
Temporary Casing
No data matches search criteria.
Perforations
No data matches search criteria.
Screens
No data matches search criteria.
Well Test
(Click to Expand...)
Well Test
Temperature:
56 F
Lab Analysis:
Lab Analysis Done By:
Sun Country Engineering
Total Dissolved Solids:
Water Quality Concerns:
Well Test
Test Type
Yield (gpm)
Drawdown
Drill Stem/
Pump Depth
Duration (hr)
Calculated Specific Capacity (gpm/ft)
Pump
160.0
148.0
24.0
1.08
Analysis
No data matches search criteria.
Static Water Level
(Click to Expand...)
Static Water Level
Depth First Water:
Pre-Static Water Level:
Pre-Static Water Level Date:
Post-Static Water Level:
5.50
Post-Static Water Level Date:
06/20/1986
Static Water Level
No data matches search criteria.
Lithology
(Click to Expand...)
Material
Row
From
To
Material
Static Water Level
1
385.00
395.00
FINE BLACK SAND/PUMICE
2
395.00
425.00
GREENISH-GREY CLAY/SAND
3
425.00
435.00
HEAVING BLACK SAND
4
435.00
515.00
HARD PINK/GREY CLAY
5
515.00
555.00
HARD GREY CLAY
6
555.00
570.00
GREY CLAY/ PUMICE
7
570.00
597.00
GREY LAVA
8
597.00
602.00
PUMICE/BROKEN ROCK
20.00
9
602.00
610.00
BROKEN GREY LAVA
10.00
10
610.00
618.00
COARSE BLACK SAND/ SMALL GRAVEL
5.50
11
618.00
647.00
BROWN BLACK ROCK/TAN CLAY
Well Constructor
(Click to Expand...)
Bonded Driller Name:
BILLY HALL
Bonded Driller Company:
VALLEY VIEW DRILLING
Bonded Driller Number:
685
Bonded Date Signed:
03/18/1986
Unbonded Name:
Unbonded Company:
Unbonded Number:
Unbonded Date Signed:
Other Name:
Other Affiliation:
Other License Nbr:
Geologist Engineer:
Comments
(Click to Expand...)
No data matches search criteria.
Documents
(Click to Expand...)
Title
Document Type
Source
Download Image
DESC 6092
WELL REPORT
DRILLER
Image